Início 下载 Download os arquivos LLEAP - Laerdal Learning Application

Download os arquivos LLEAP - Laerdal Learning Application



DFU

Simstart用户指南

3.4 MB-英语
10.01.2020

Simulated AED or Monitor Defibrillator training functionality available in Laerdal Learning Application- LLEAP
快速指南WiFi设置

1.2 MB-英语
24.06.2019

会话查看器 - 用户指南

2.7 MB - Multilingual
10.07.2015

文件

LAERDAL网络要求文档Rev O

0.8 MB
15.06.2022

本文档介绍了针对Laerdal仿真设备的预先存在的基础架构建立网络的要求。
LLEAP Sell Sheet

5.3 MB - English
17.09.2014

软件

Laerdal学习应用程序(LLEAP)v。8.2.0

1 500.1 MB
30.03.2022

Changes in this release:

  • EFM improvments.
    • The appearance of Fetal Heart Rate and TOCO curves have been improved to resemble real data more accurately.
    • 时间尺度的可见性得到了改善。
    • The visibility of the values on the scale of EFM & TOCO have been improved.
    • The paper speed can be changed by clicking the paper speed value on the EFM screen, which then toggles the view between 1cm/min, 2cm/min & 3cm/min speeds.
    • FHR添加了彩色背景,表明心率值的警报级别不同。级别可以由配置文件编辑器中的用户设置,并将贯穿所有情况。
  • 拉普。
    • 安全改进。
    • 修复了一个问题,即关闭LLEAP和模拟器时,SimCapture记录不会自动停止。
    • Fixes an issue when using themes where aortic value was not set correctly on first load of theme.
  • 西曼3G家庭。
    • Fixes an issue where eye blinking would be off at start up for SimMan Essential.
    • Fixes an issue where pacing a SimMan 3G did not affect the pulse.
    • Fixes an issue where some SimMan 3G simulators were going into a continuous loop.
  • Patient Monitor.
    • 修复错误,该错误并非总是在profile Editor中设置的可接受范围内返回可接受的范围内时,并不总是关闭警报。
    • 修复错误,如果将语言设置为荷兰语,则患者监视器将在启动时崩溃。
  • simdesigner。
    • 功能可以自动保存更改SimDesigner关闭。
    • 解决了一个问题,无法在节奏变化上设置延迟。
    • 解决了一个问题,其中有时无法在阶段编辑器中移动事件。
    • 解决GUI和翻译问题。
Laerdal患者监视器v。8.2.0

896.1 MB
30.03.2022

Laerdal患者监视器软件与LLEAP和SIMPAD兼容。

下载LLEAP时,包括Laerdal患者监视器软件。此下载允许您在同一台计算机上安装LLEAP的情况下安装Laerdal患者监视器软件。

Changes in this release:

  • 与LLEAP 8.2.0保持一致的新版本
  • 修复错误,该错误并非总是在profile Editor中设置的可接受范围内返回可接受的范围内时,并不总是关闭警报。
  • 修复错误,如果将语言设置为荷兰语,则患者监视器将在启动时崩溃。
Laerdal学习应用程序(LLEAP)v。8.1.0

1 489.9 MB
07.01.2022

重要的:

LLEAP版本8.1.0包含以下内容:

  • Bug fixes:
    • Simman 3G Plus现在可以选择虚拟模拟器。
    • CPR指南已被更新,以遵守欧洲复苏委员会(ERC 2021)和美国心脏协会(AHA 2020年的最新指南。
    • 改进了指导老师应用程序GUI量表在显示屏以外的显示缩放的计算机上的缩放程度(推荐设置仍以100%的比例缩放)。
    • 修复使用者时的患者监视器和二氧化碳。
    • 修复使用SIMMOM时缺少脉冲控制的方法。
    • 在Simman 3G上添加了静态IP地址。
    • 修复Simman 3G加上PB的更改和右臂臂脉冲中缺少响应的修复。
    • Fix for unaccesible control buttons on computers with low resolution.

更改版本8.0.0:

  • Support for SimMan 3G PLUS.
  • New updater for SimMan 3G simulators, providing a more reliable update experience, and improved progress feedback.
  • 支持护理Anne老年病,允许使用新老年皮肤的护理Anne模拟器使用老年发声。
  • Link Box Classic is no longer supported.
  • LLEAP on Windows 7 computers is no longer supported.
  • 使用Windows XP嵌入的Simman 3G模拟器不再支持。
  • New version of SimDesigner:
    • 删除了对Microsoft Silverlight的依赖,因此可以使用Silverlight未安装SilverSigner。
    • Minor changes to user interface when editing states to make it easier to add many states.
    • Missing icons for some heart rhythms added.
    • 使用“外部窗口”的选项已被删除。
  • Bug fixes:
    • Fixes a bug introduced in LLEAP 8.0.0 where video recording was not included in the debrief when using SessionViewer and SimView.
    • 修复了一个问题,即安装LLEAP时缺少与Simman 3G一起使用的WiFi适配器的驱动程序。

Note:

Updating to Windows 10?
  • Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor?
    • Microsoft通过Windows 8的发布结束了对此类网络的支持。从Windows 10开始,该设备将需要使用单独的仿真网络。Laerdal可以帮助您将所有仿真设备连接到专用网络。了解更多并开始拉尔达尔。com/Network.

Windows Update
  • Before installing LLEAP, to secure a successful installation, please make sure the PC is fully updated through Windows Update. If you have problems starting LLEAP after installation, please download and run Visual C++ 2015 redistributable from this location:Microsoft Visual C ++ 2015可重新分布更新3。。选择并运行vc_redist.x86,然后尝试运行lleap。
Laerdal患者监视器v。8.1.0

895.6 MB
07.01.2022

重要的:

Laerdal患者监视器软件与LLEAP和SIMPAD兼容。

下载LLEAP时,包括Laerdal患者监视器软件。此下载允许您在同一台计算机上安装LLEAP的情况下安装Laerdal患者监视器软件。

Changes in this release:

  • 与LLEAP 8.1.0保持一致的新版本

Note:

Updating to Windows 10?
  • Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor?
    • Microsoft通过Windows 8的发布结束了对此类网络的支持。从Windows 10中,设备将需要使用单独的仿真网络。
Windows 7的
  • 拉尔达尔Patient Monitor 7.3 is the last version that supports Windows 7
LLEAP补丁7.3.0

0.4 MB-英语
28.07.2021

LLEAP补丁7.3.0,适用于不能使用LLEAP 8.0的老年Simman 3G

此更新是为了解决一个问题,即与ASL 5000一起使用2厘米H2O或更高的呼吸机设置与ASL 5000一起使用Simman 3G上的胸部和肺部声音停止。该问题也可以通过升级到LLEAP 8.0.0来解决。仅当无法升级到8.0.0时,才应使用此补丁,例如,当将旧的Simman 3G与XP嵌入XP使用时,LLEAP 8.0.0及以前不支持该XP。

重要的:ASL 5000 plugin needs to be uninstalled before patch installation and reinstalled afterwards. Remember to back up custom lung models when prompted during uninstall process and import again during install process after upgrade to patch.

Note:

    Simman 3G Updater可能需要进行几次尝试,然后将补丁安装在模拟器上
Laerdal学习应用程序(LLEAP)v。7.3.0

1 526.9 MB
16.03.2021

重要的:

Changes in this release:

  • New Device Connection Manager (DCM) application to manage network configurations more efficiently on multiple manikins.
  • 通过WiFi USB适配器从SFNW&for Simman3G提供对企业网络安全的增强支持。
  • 修复了SIMMAN3G系统时间未同步的问题。
  • 改进了具有较高延迟的网络上的模拟器连接。
  • 包括WiFi驱动程序到LLEAP安装程序(SOM在SIMMAN3G上)。
  • 修复了一个问题,除非明确选择,否则模拟不会使用所需的仿真配置文件。可能导致使用错误的单位和类似问题。
  • LLEAP支持运输层安全性(TLS)1.2或更高,以登录到方案云。
  • 修复了导致帮助文件不起作用的问题。

Note:

Updating to Windows 10?
  • Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor?
    • Microsoft通过Windows 8的发布结束了对此类网络的支持。从Windows 10开始,该设备将需要使用单独的仿真网络。Laerdal可以帮助您将所有仿真设备连接到专用网络。了解更多并开始拉尔达尔。com/Network.

最后支持Windows 7的LLEAP版本
  • LLEAP 7.3将是支持Windows 7的最后一个版本。

Last version supporting old SimMan 3G family simulators

Due to end of life for Windows XP Embedded used on older SimMan3G simulators, LLEAP will no longer supported as of this version, this applies to the following simulators - unless they have been upgraded to use Windows 7:

  • SimMan3G simulators with serial numbers lower than 212-16140000
  • SimMan3G Essential simulators with serial numbers lower than 213-16140000
  • SIMMAN3G基本出血模拟器,序列号低于214-1614000

Windows Update
  • Before installing LLEAP, to secure a successful installation, please make sure the PC is fully updated through Windows Update. If you have problems starting LLEAP after installation, please download and run Visual C++ 2015 redistributable from this location:Microsoft Visual C ++ 2015可重新分布更新3。。选择并运行vc_redist.x86,然后尝试运行lleap。
拉尔达尔PatientMonitor v. 7.3.0

932.6 MB
11.03.2021

重要的:

Laerdal患者监视器软件与LLEAP和SIMPAD兼容。

下载LLEAP时,包括Laerdal患者监视器软件。此下载允许您在同一台计算机上安装LLEAP的情况下安装Laerdal患者监视器软件。

Changes in this release:

  • 与LLEAP 7.3.0保持一致的新版本
  • General maintenance, bugfixes and improvements.

Note:

Updating to Windows 10?
  • Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor?
    • Microsoft通过Windows 8的发布结束了对此类网络的支持。从Windows 10中,设备将需要使用单独的仿真网络。
Windows 7的
  • Laerdal患者监视器7.3将是支持Windows 7的最后一个版本
Laerdal学习应用程序(LLEAP)v。6.8.1

1 225.5 MB
18.12.2019

Changes in this release:

  • Simulator lost connection - Improving error message.
  • Simbaby-改善了允许喉部和露天道的气管造口术功能。
  • Simbaby-固定的问题,咽部障碍物未显示虚拟模拟器的申请。
  • 主题 - 现在显示与可用模拟器有关的功能。
  • SimJunior - Fixed issue where simualtor did not show in simulator list.
  • SIMMOM-现在可以使用高级选项连接SIMMOM。
  • LLEAP - Fixed issue related to changeing vital signs before starting session.
  • LLEAP-与应用程序开始有关的固定问题。
  • SIMMAN 3G-修复了一个问题,该问题已记录了不支持它的Simman 3G的气管瘤打开。
  • LLEAP-修复了一个问题,如果LLEAP选择开始新的会话,则SessionViewer仍然显示状态“记录”。
  • 停止压缩事件 - 修复了停止模拟压缩也不会导致“停止压缩”的问题。

自6.8.0以来的更改:

  • 增加了对气管切开术的Simbaby的支持。
  • SIMNEWB对UI的一些改进和调整。
  • 添加了秒表功能。单击“会话控制”窗口上的“播放/暂停”按钮旁边的时光段以显示秒表窗口。
  • 增加了一个新的pre-recorded vocal sound “OK” for Adult(Male/Female) and Child.
  • 改善了UI用于胃扩张功能。现在拥有一个单独的“释放空气”按钮。对于SimJunior,还有一个单独的“膨胀”按钮。
  • Fixed an issue where LLEAP would sometimes crash when ending a session.
  • 修复了一个问题,即在运行方案时舌头后备工作正常。
  • 修复了用户定义变量过渡的问题,并不总是最终出现在正确的值之上。
Laerdal患者监视器v。6.8.1

673.3 MB
18.12.2019

Laerdal患者监视器软件与LLEAP和SIMPAD兼容。

下载LLEAP时,包括Laerdal患者监视器软件。此下载允许您在同一台计算机上安装LLEAP的情况下安装Laerdal患者监视器软件。

与LLEAP 6.8.1保持一致的新版本

Changes in this release:

  • Defibrillator Monitor - Fixed issue with layout.
  • Patient Monitor Layout - Fixed issue with hidden buttons after minimizing application.
  • 监视声音 - 节拍器声音未启动的固定问题。
  • ECG AV块 - 在高心率上使用错误的人力资源固定问题。
  • SimMom - Fixed issue where SimMom was listed twice in simulator list.

自6.8.0以来的更改:

  • Simulated AED and Defibrillator monitor (SimStart) now have translated voice prompts.
  • 改进的模拟AED/除颤器监视器上的体积指示器。
  • Fixed an issue where the NIBP auto measurement would be triggered too often.
  • 修复了在激活测量之前有时会显示NIBP测量的问题。
  • Fixed an issue where some buttons would not show after minimizing the Patient Monitor window.
  • 修复了以AED模式下的患者监视器有时会崩溃的问题。
SimView下载


24.11.2017

使用此链接将最新软件下载到SimView
SimView移动下载


24.11.2017

使用此链接将最新软件下载到Mighview Mobile
会话查看器下载


09.11.2017

使用此链接将最新软件下载到会话查看器

© 2001-2022 Laerdal Medical. Todos os direitos reservados.