Simpad Plus 8.1.5
26.05.2022
Improvements and new features:
- Voice Conferencing Audio would sometime not reconnect on poor network.
- 60年以反映正确的心电图曲线的壁炉节奏图标已更新60年。
- Warning banner for simulator connection did not automatically disappear after simulator reconnect, fixed so that user no longer has to manually dismiss.
- SimNewB Lung recruitment was easier to complete on second attempt – corrected so that equal effort is required on each attempt.
- Shallow and irregular chest rise on SimNewB corrected.
- Simpad SkillReporter -BLS学习者评估记录文件使用保存和上传按钮。
Bug修复:
- 支持ing more than 8 SimCapture nodes.
- SimNewB ventilation airway panel, displaying correct volume.
- 保存自定义特定的无线信道
- Adding extrasystole artifact to Anterior AMI heart rhythm.
SimPad SkillReporter (BLS) fix:
New features, improvements and bug fixes from 8.1.0:
- 模拟器的WiFi信号强度。
- Accurate CPR score when doing ventilations and compressions at the same time.
- ERC指南2021。
- SimCapture select locations and capture nodes.
- Fix when typing wrong password on enterprise wifi network.
- Changes to manikin selection screen.
- 显示主题的自定义声音和Manikin的默认声音。
- 模拟器可能会挂在关闭时。
- Manual Mode some values were not possible to add and store to theme states.
Note:
Compatibility with SimPad and LinkBox
- SimPad PLUS and LinkBox PLUS 8.0.0 and newer is no longer compatible with SimPad and LinkBox. For compatibility please use 7.4.5.
Updating to Windows 10?
- SimLink or Custom ad hoc network from SimPad is not supported by Windows 10.
Windows 7
- 患者监视器8.0.0,新较新将不支持Windows 7
模拟器更新
- 更新护理Anne Simulator,Simnewb和Simbaby最多需要60分钟。等待在Manikin上稳定的绿灯。
- Resusci Manikins更新最多可能需要5分钟。
SimPad Theme Editor 1.3.1
3.8 MB - English
11.10.2021
SIMPAD主题编辑器是使用手动模式操作时为SIMPAD系统创建主题的PC软件工具。该程序使您可以轻松地通过状态和干预措施制作新主题。新版本不再是在线工具。请在计算机上下载并安装Simpad主题编辑本地。
- Dependency on Microsoft Silverlight removed, so that Theme Editor can be used without Silverlight installed.
- Minor changes to user interface.
SimPad PLUS 7.4.5
11.06.2021
Changes in this release:
- 如果用户退出会话,则标准化患者的会话日志文件不是存储的。
Changes from version 7.4.0:
- Nursing Anne Simulators will have a new option in Session Information to change the default age and gender of the manikin (per now it only affects prerecorded sounds).
- Age and Gender Setup button is only visible when connected to a Nursing Anne Simulator .
- Voice Conferencing Application (VCA) improvements.
- 偶尔对VCA的混叠已得到改善。
- Prerecorded sounds will in some cases sound loud through the instructor headset, a button to automatically mute instructor headset when playing prerecorded sounds has been added.
- Fix Vocal sound on SimMan ALS.
- 修复BLS讲师的流量分数得分。
- Fixed issue with Nursing Anne Simulator, SimNewB and SimBaby where they would sometimes not connect after running first session.
- Corrected problem where SimPad would sometimes not connect to internet enabled services such as Laerdal Scenario Cloud.
- Fixed ShockLink update issue where some devices would fail to update to newest version.
Note:
Updating to Windows 10?
- Using SimLink or Custom ad hoc network on SimPad, and considering upgrading to Windows 10 on your computers for Laerdal Patient Monitor?
- Microsoft ended their support for this type of network with the release of Windows 8. From Windows 10 the equipment will need to use a separate simulation network.
Windows 7
- 患者监视器8.0.0,新较新将不支持Windows 7
- Updating Nursing Anne Simulator, SimNewB and SimBaby take up to 20 minutes. Wait for a steady green light on the manikin.
- Resusci manikins are updated with new firmware, the update takes up to 5 minutes.
SimPad PLUS 6.8.1
04.12.2019
Changes in this release:
- BugFix不良语音会议音频。
- BugFix Audio feedback using external microphone to SimJunior manikin .
- Bugfix SimBaby artificial chestmovement while ventilating.
- BugFix Simstart虚拟垫未注册。
- BugFix Simstart AED未在使用Simpad BLS讲师时检测到。
- Bugfix Standarized Patient spins forever.
Changes since 6.8.0:
- SimPad :
- SIMPAD手动模式:震动没有设置为下一个心律。
- 许可证:可以删除SIPPAD许可证。
- Simpad Classic:无法在WiFi上访问Simstore。
- Nursing Anne Simulator:
- 语音会议系统更高的默认卷
- More silent running chest rise
- SimBaby:
- Possible for the instructor to trigger intubation event in Manual Mode
- 使用Simpad时添加了疾驰的心声音
- 气管切开术护理:通风时固定气道泄漏
- 暂停会议时,运动和癫痫发作应停止
- Release button for stomach distension
- 固定ETCO2曲线在通风时在患者监视器上
- 通风时没有肺部声音
- SimNewB:
- Release button for stomach distension
- SimBaby: Possible for the instructor to trigger intubation event in Manual Mode
- Other:
- RA QCPR:更新的固件
- Resuci Junior QCPR: Updated Firmware
- SimJunior: Release button for stomach distension
- Sounds Trainer: Possible to adjust sound volume levels
Note:
- Updating Nursing Anne Simulator, SimNewB and SimBaby take up to 20 minutes. Wait for a steady green light on the manikin.
- Resusci manikins are updated with new firmware, the update takes up to 5 minutes.
会话查看器下载
09.11.2017
使用此链接将最新软件下载到会话查看器
SimPad Theme Editor
- English
05.01.2016
IMPORTANT INFORMATION - This software will only be accessible using Internet Explorer
The Theme Editor is an online PC software tool for creating Themes for the SimPad system when operated using the Manual Mode. The program allows you to easily make new Themes with States and Interventions.
要脱机:右键单击网页中的Anywere,然后选择“安装Simpad主题编辑器”到这张计算机...